Transformer winding machine consists of many electronic components of the integrated circuit, its insulation performance and environmental humidity has a great relationship. If the humidity is too high, it is easy to lead to circuit board short circuit and burn; if the humidity is too small, it is easy to generate static electricity, but also break through some electronic components. Therefore, too high humidity, too small, which will bring potential threats to the transformer winding machine. Second, the ground is very shocking. In many factories, the motor needs to produce physical displacement action, such as dragging, vibration, which will not only bring great noise, but also the machine work caused by the violent vibration may cause damage to the transformer winding machine. When placing the transformer winding machine, try to keep the transformer winding machine away from large work sites; if the workplace cannot be replaced, sponges and buffers should be placed under the transformer winding machine body to reduce the hazards caused by small vibrations.
The common functions of transformer winding machine are turns presetting, automatic stop, forward and reverse winding, automatic cross slot, etc. In actual use, it should be noted that the first thing is to start the idle train and stop the slow train to start the idle train. This function is to slow down the operation after the equipment is started. The purpose is to reduce the impact on the tension structure and the enameled wire. The general situation can be set to 1 to 3 times depending on the actual need. The stop slow function is the slow operation of the equipment before the completion of the winding sequence. This function reduces the impact on the brake and allows the machine to end the winding smoothly, especially for winding processes that require precise positioning. This parameter must be set. Depending on the operating speed of the device, the parameter should be adjusted accordingly. 2 to 5 turns and again the direction of the cable and the winding. These two parameters are the settings for the direction of cable displacement and the direction of spindle rotation. The cable winding axis and the spindle of the automatic winding machine are controlled by the controller. A specific connection relationship exists. When setting, the direction of displacement of the cable spindle must be found out. Many users report device alarms during commissioning. This is due to a setting error. The device protection caused by the error, the winding machine detects zero
There are two future directions for transformers: one is ultra-high voltage and high capacity, and the other is high efficiency, intelligence, small and low noise. In addition to the structural design, the quality and economic and technical performance of the transformer depends largely on the manufacturing process and the technical level of the manufacturing equipment. In order to meet the increasingly stringent requirements for transformer quality and performance specifications, winding machine manufacturers must improve the technical level of transformer winding machines to enable them to manufacture transformers that meet the country’s power development needs.
WhatsApp/ウィチャット+86 13075286997
メール: sales@vacuz.com